Advanced Course on
IEC 61850 Based
Systems Course Contents and Schedule |
Workshop
Introduction
|
|
Workshop Contents
|
|
Workshop Development |
|
Workshop Documentation |
|
Workshop Methodology |
|
Excluded Contents |
|
Student Evaluation |
|
Summary |
Introduction |
|
Substation Evolution |
|
Protocol Evolution |
|
Ethernet in Substations |
|
Modeling Requirements |
|
IEC 61850 Capabilities |
|
IEC 61850 Documentation |
|
Summary |
Introduction |
|
Distributed Systems |
|
Client Server Systems |
|
Remote Procedure Call |
|
Distributed Object Systems |
|
Pee-to-Peer Systems |
|
Service Oriented Systems |
|
Distributed Real Time Systems |
|
Distributed Systems Based on IEC 61850 |
|
Summary |
Introduction |
|
Communication Requirements |
|
Run Time Requirements |
|
Abstract Interfaces |
|
Specific Interfaces |
|
Mapping to MMS |
|
Mapping to CORBA |
|
Mapping to Ethernet |
|
Summary |
Introduction |
|
Functions |
|
Compatible Logical Nodes |
|
PICOM Model |
|
Logical Devices |
|
Servers |
|
Proxies and Gateways |
|
Intelligent Electronic Devices |
|
Network |
|
Summary |
Introduction |
|
Namespaces |
|
Data Class |
|
Common Data Classes |
|
Data Attributes |
|
Data Types |
|
Functional Constraints |
|
Summary |
Introduction |
|
Abstract Services |
|
Association Model |
|
Logical Node Model |
|
Logical Node 0 |
|
Data Set Model |
|
Substitution Model |
|
Control Model |
|
File Transfer Model |
|
Reporting Model |
|
Logging Model |
|
Setting Model |
|
Timing Model |
|
Summary |
Introduction |
|
Message Types |
|
GSE Model |
|
GOOSE Model |
|
GSSE Model |
|
Sampled Value Model |
|
Summary |
Introduction |
|
Factory Tests |
|
System Tests |
|
Site Tests |
|
Conformance Tests |
|
Interoperability Tests |
|
Performance Tests |
|
Conformance Statements |
|
Conformance Certification |
|
Interoperability Declaration |
|
Summary |
Introduction |
|
Extensible Markup Language |
|
Substation Configuration Language |
|
Substation Model |
|
Product Model |
|
Communication Model |
|
Data Type Model |
|
SCL File Types |
|
Summary |
Introduction |
|
Communication Architecture |
|
Process Level Architecture |
|
Bay Level Architecture |
|
Station Level Architecture |
|
Scada Level Architecture |
|
Summary |
Introduction |
|
Protection |
|
Teleprotection |
|
Reverse Interlocking |
|
Switchgear Controlling |
|
Substation Interlocking |
|
Synchrocheck Switching |
|
Busbar Voltage Simulation |
|
Remote Operation |
|
Fault Recording Transmission |
|
Commissioning and Testing |
|
Line Transfer |
|
Breaker Failure |
|
Load Shedding |
|
Summary |
Introduction |
|
Hydropower Logical Nodes |
|
Hydrological Control |
|
Electrical Control |
|
Automatic Control |
|
Protection System |
|
Summary |
Introduction |
|
Windpower Logical Nodes |
|
Wind Control |
|
Electrical Control |
|
Automatic Control |
|
Summary |
Introduction |
|
DER Configurations |
|
DER Systems |
|
Electrical Connection Point |
|
Unit Controller System |
|
Generator System |
|
Excitation System |
|
Inverter Converter System |
|
Fuel System |
|
Battery System |
|
Measurement System |
|
Reciprocating Engine |
|
Fuel Cell System |
|
Photovoltaic System |
|
Combined Heat and Power |
|
Summary |